You are here - All Product > Compressors / Dryers / Air Receivers > Compressor pressure switches
Description
Single phase pressure switch with high control over cut in and cut out pressure differential.
First the cut out pressure must be set by adjusting the screw on the switch.
The cut in pressure can now be set by adjusting the hex nut on the switch.
Some examples of pressure differential below
When the cut out pressure is set to 2 bar, the cut in pressure can be set from 0.3 bar to 1 bar.
When the cut out pressure is set to 4 bar, the cut in pressure can be set from 0.3 bar to 2.8 bar.
When the cut out pressure is set to 6 bar, the cut in pressure can be set from 0.3 bar to 4.6 bar.
When the cut out pressure is set to 8 bar, the cut in pressure can be set from 0.3 bar to 6.5 bar.
When the cut out pressure is set to 10 bar, the cut in pressure can be set from 1.5 bar to 8.5 bar.
When the cut out pressure is set to 12 bar, the cut in pressure can be set from 3.6 bar to 10.3 bar.
For other pressures please see graph in the datasheet.
Technical Details
Part Number: XMPA12B2131
Pressure Rating: 12 bar
Fluid Connection Type: 1x 1/4" BSPP Female (conforming to ISO 228)
Controlled Fluid: Air (0 to 70 Deg C) Fresh Water (0 to 70 Deg C) Sea Water (0 to 70 Deg C)
Cable Entry: 2 Entries Tapped for Pg 13.5 Cable Glands
Contacts Type: 2 NC Snap Action
Adjustable Range Of Switching Point On Falling Pressure: 0.3 to 10.3 bar
Adjustment Range High Setting: 1.3 to 12 bar
Possible Differential Minimum At Low Setting: 1 bar
Possible Mifferential Minimum At High Setting: 1.7 bar
Possible Differential Maximum At High Setting: 8.4 bar
Destruction Pressure: 30 bar
Type Of Decompression Valve: Without
Control Type: Without
Terminal Block Type: 4 Terminals
Pressure Actuator: Diaphragm
Rated Insulation Voltage: 500 V Conforming to IEC 60947-1
Rated Impulse Withstand Voltage: 6 kV Conforming to IEC 60947-1
|
Datasheets
1) XMPA12B2131
2) XMP Instruction Manual
|